Published applications
- HVAC
- Redunization
- Liquid/liquid
Existing OEM model reference
Use the published dimensions and construction below to identify a possible HEXNOVAS replacement. Thermal duty, connection type, design pressure, brazing material and refrigerant distribution must be confirmed before selection.
Published technical reference
Model-specific engineering review
The existing reference is Alfa Laval CB60: 113 × 527 mm overall with 50 × 466 mm port centres. The record describes copper-brazed stainless-steel plates and a published maximum pressure of 32 bar.
HEXNOVAS BL50 is the nearest dimensional candidate shown by the comparison tool. Its 111 × 525 mm outline differs even though the listed port centres agree. That candidate ranking is not a thermal or connection-compatibility result.
Port-centre measurements do not specify connection diameter, thread or flange standard. Confirm the complete installed configuration.
The source context includes HVAC, refrigeration and liquid/liquid duties. The specific plate count, connections and operating envelope must be checked for the installed CB60 configuration.
Brazed plate construction and family overviewThe on-page drawing is a generated, not-to-scale identification schematic. Its dimensions come from the reference catalogue; its depicted plate/port geometry is not a certified manufacturing drawing.
Alfa Laval CB60 product leaflet. Source revision/date is not recorded with this catalogue entry.
Request the reviewed model drawing and configuration-specific rating before manufacture or replacement.
Send the complete CB60 designation, nameplate, connection photographs and both fluid duties. Specify design conditions and allowable pressure drop; do not treat the catalogue maximum pressure as a complete pressure/temperature rating.
Thermal selection inputs and pressure-drop reviewThird-party brand and model names are used solely to identify existing equipment and dimensional references. HEXNOVAS is an independent supplier and is not affiliated with or endorsed by those manufacturers. Dimensional similarity does not establish thermal, mechanical or connection equivalence.