Industrielle Anwendung

Wärmeaustauscher für HVAC-Systeme

Plattenwärmetauscher für Fernwärme und -kühlung, HVAC-Hydroniksysteme, Wärmepumpen, Warmwasser und Gebäudeenergierückgewinnung.

Prepare Your Selection Request
Wärmeaustauscher für HLK-Systeme für die Wärmeaustauschertechnik

Anwendungstechnik

Process Role

A hydronic heat exchanger transfers heat between primary and secondary circuits while allowing each loop to use its own pressure, water treatment and circulation arrangement. In a district-energy substation, it links the network temperature program to the building load; it does not create additional heating or cooling capacity.

Heat-pump refrigerant interfaces, domestic hot-water heaters and chilled-water isolation units have different rating conditions. Seasonal operation can change source temperature, flow and load together. Selection therefore needs the operating range as well as the design-day duty.

Thermische Schnittstellen

Typical Thermal Duties

Fernwärme und Fernkälte

Match network supply and return temperatures to the building circuit, including the return-temperature objective and available pump head. The exchanger and control valve share the hydraulic budget.

Heat pumps and domestic hot water

Separate the refrigerant-side evaporator or condenser duty from a water-to-water interface. Domestic-water service also needs compatible contact materials and the documentation required for its jurisdiction and use.

Chilled water, condenser water and free cooling

A separating exchanger can isolate water quality between circuits. Free-cooling changeover depends on source conditions and required approach; heat recovery needs a concurrent heating demand.

Rating basis

Key Engineering Inputs

  • Primary and secondary inlet/outlet temperatures, flow rates and load profiles at design and part load.
  • Operating/design pressures and allowable pressure drop on each circuit, including valve and piping allowances.
  • Glycol type and concentration, water chemistry, fouling allowance and freeze-protection strategy.
  • Domestic-water contact requirements, cleaning access, connection standards and any customer-specified certification.

Design review

Application-Specific Design Challenges

Small driving force

A small temperature difference increases required UA. More area, different plate geometry or a multi-pass arrangement may help, but each changes velocity, pressure drop or temperature matching. Long plates and multi-pass designs are options, not universal requirements.

Seasonal water and control conditions

Glycol affects viscosity and thermal properties; use the actual mixture at the operating temperature. Review low-flow operation, fouling and startup control so a nominally adequate unit is not assessed only at its easiest operating point.

Published Evidence Scope

The published industrial heat-pump cases do not establish performance for a district-energy or domestic-water installation. No building-specific project result is claimed here.

Technologieanpassung

Common Heat Exchanger Technologies

Gedichtete Platten

Suitable to evaluate for district substations and openable building-water interfaces, subject to plate and seal compatibility.

Gelötete Platten

Consider for packaged heat pumps and clean closed loops where the selected pressure rating and maintenance approach fit.

Stainless fusion-bonded

A copper-free candidate where the actual water chemistry or specification calls for it; confirm use-specific compliance.

Prepare your enquiry

What HEXNOVAS Needs for Selection

  • Send the primary/secondary schematic and temperature/flow schedules for heating, cooling and part-load operation.
  • State glycol concentration, water quality, pressure classes and the pressure drop available at the exchanger.
  • For domestic hot water, include peak demand, control arrangement and required material/compliance documentation.
Send Your Operating Conditions

Technische Unterstützung

Sende die Betriebsbedingungen. Wir werden die Technologie bewerten.

Request Selection
Kontakt HEXNOVAS